All those versions are paramount versions. PDF version of CDCS practice materials - it is legible to read and remember, and support customers’ printing request, so you can have a print and practice in papers. Software version of CDCS practice materials - It support simulation test system, and times of setup has no restriction. Remember this version support Windows system users only. App online version of CDCS practice materials - Be suitable to all kinds of equipment or digital devices. Be supportive to offline exercise on the condition that you practice it without mobile data.

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.
Topic 2
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 3
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.

>> CDCS Valid Test Experience <<

New CDCS Exam Discount & CDCS Exam Tutorial

The exam outline will be changed according to the new policy every year, and the CDCS questions torrent and other teaching software, after the new exam outline, we will change according to the syllabus and the latest developments in theory and practice and revision of the corresponding changes, highly agree with outline. The CDCS Exam Questions are the perfect form of a complete set of teaching material, teaching outline will outline all the knowledge points covered, comprehensive and no dead angle for the CDCS candidates presents the proposition scope and trend of each year.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q12-Q17):

NEW QUESTION # 12
When shielding material reaches its saturation point, what will be the impact?

  • A. The shielding material will reach its maximum electrically charged state.
  • B. The shielding material will no longer be able to attenuate (reduce) additional EMF.
  • C. The shielding material will increase its permeability factor.
  • D. The shielding material will reach its optimal shielding performance state.

Answer: B

Explanation:
When shielding material reaches its saturation point, it can no longer effectively attenuate additional EMF. At saturation, the material's ability to absorb or redirect magnetic fields is exhausted, meaning it cannot provide further shielding beyond this point. Additional EMF exposure would pass through the material without significant reduction.
Detailed Explanation:
Saturation occurs when the material's magnetic domains are fully aligned with the magnetic field, leaving no capacity to absorb or deflect further EMF. This can happen with high EMF levels, beyond the material's design limits, resulting in a breakdown of shielding effectiveness.
EPI Data Center Specialist References:
EPI guidelines on EMF management indicate that selecting appropriate shielding materials with sufficient capacity is essential to prevent saturation and ensure continuous protection. Saturation limits should be considered during design to avoid compromised shielding performance.


NEW QUESTION # 13
You are allowed to use a calculator for this question. The total power consumption of the ICT equipment in a rack is 6 kW. The equipment is traditional ICT equipment with a Delta-T of approximately 11 °C / 20 °F. Calculate the approximate CFM required to cool the equipment in the rack.

  • A. Approximately 160 CFM
  • B. Approximately 1,000 CFM
  • C. Approximately 1,500 CFM
  • D. Approximately 500 CFM

Answer: B

Explanation:
To calculate the cooling airflow requirement for ICT equipment, you can use the formula:
CFM=Power (kW)×3160ΔT(°F)text{CFM} = frac{text{Power (kW)} times 3160}{Delta T (text{°F})}CFM=ΔT(°F)Power (kW)×3160​ For equipment consuming 6 kW with a Delta-T of 20°F:
CFM=6×316020=948≈1,000 CFMtext{CFM} = frac{6 times 3160}{20} = 948 approx 1,000 , text{CFM}CFM=206×3160​=948≈1,000CFM Detailed Explanation:
This formula provides an estimate of the cubic feet per minute (CFM) of air required to cool the equipment based on its power consumption and the temperature difference (Delta-T) between intake and exhaust. The Delta-T represents the cooling effectiveness of the airflow.
EPI Data Center Specialist References:
EPI recommends using this calculation for determining airflow requirements in data centers, ensuring that cooling systems are adequately sized to maintain equipment within safe temperature limits.


NEW QUESTION # 14
Do you need to consider blast protection when designing a data center?

  • A. Yes, if the data center is a potential target or the building is located within the vicinity of (close by) a potential target.
  • B. Yes, blast protection is a requirement of ANSI/TIA-942.
  • C. No, blast protection is not a requirement of ANSI/TIA-942.
  • D. No, there is no reason for implementing blast protection as nobody can predict the impact of a bomb explosion.

Answer: A

Explanation:
Blast protection should be considered if the data center or its location is a potential target or is near high-risk areas. Blast protection measures can protect both personnel and infrastructure from potential explosion impacts, which could be essential in areas with heightened security risks.
Detailed Explanation:
In areas where there may be risks of terrorist attacks or explosions due to nearby high-risk facilities, implementing blast protection measures helps safeguard the data center's infrastructure. These measures can include reinforced walls, blast-resistant windows, and secure entryways designed to withstand explosive forces.
EPI Data Center Specialist References:
While not specifically mandated by ANSI/TIA-942, EPI training advises considering local risk factors, including proximity to potential targets, when evaluating the need for blast protection. This approach is aligned with risk assessment and mitigation practices to ensure facility security.


NEW QUESTION # 15
A data center is located in an area where the demand for power is higher than the utility power company is able to deliver. This results in frequent power outages and, therefore, power shedding (scheduled/controlled power shutdown for areas) is frequently applied. The mains power is more than 650 hours/year not available.
What type of generators should be installed?

  • A. Continuous generators should be installed; no N+1 configuration is needed as the generators will run all the time
  • B. A combination of standby-, prime-, and continuous-generators, as the duration of the power outage is unpredictable. The total available capacity of the generators should be at least 500% of the data center load
  • C. Standby generators should be installed in at least an N+1 configuration
  • D. Continuous generators should be installed, at least in an N+1 configuration

Answer: D

Explanation:
In areas with frequent and extended power outages, continuous generators with at least an N+1 configuration are necessary to ensure consistent power availability. Continuous generators are designed for prolonged operation, making them suitable for scenarios where utility power is frequently unavailable, as in this case with outages exceeding 650 hours per year. An N+1 configuration ensures redundancy, which is critical for maintaining uptime in a high-availability data center.
Detailed Explanation:
Continuous generators provide reliable power over long durations, unlike standby generators, which are intended only for short-term use. The N+1 configuration ensures that there is always an additional generator available in case of failure, thus maintaining power supply even if one generator goes offline.
EPI Data Center Specialist References:
EPI best practices recommend continuous generators with redundancy for data centers located in areas with high power instability to maintain reliability and continuous operation.


NEW QUESTION # 16
An MCB needs to be installed in the PDU of an air-conditioner unit.
Which breaking curve should you select?

  • A. C-Curve
  • B. D-Curve
  • C. B-Curve
  • D. A-Curve

Answer: A

Explanation:
For an MCB (Miniature Circuit Breaker) in the PDU of an air-conditioning unit, a C-Curve is recommended. C-Curve breakers are suitable for circuits with moderate inrush currents, such as those experienced in air conditioning units. They provide protection against overloads while accommodating the inrush without nuisance tripping.
Detailed Explanation:
C-Curve breakers trip when currents exceed 5 to 10 times the rated current, making them ideal for devices like air conditioners that experience moderate inrush currents upon startup. This characteristic provides a balance between protection and resilience against startup surges, preventing unnecessary trips while safeguarding the circuit.
EPI Data Center Specialist References:
EPI guidance for data center electrical systems specifies that C-Curve breakers are appropriate for equipment with inrush characteristics similar to air conditioning units, as they help prevent operational interruptions caused by typical surges during equipment start-up.


NEW QUESTION # 17
......

Many newcomers know that as an IT engineer they have to take part in exams for EXIN certifications, if pass exams and get a certification, you will get bonus. EXIN CDCS PDF file materials help a lot of candidates. If you are ready for exams, you can use our latest PDF file materials to read and write carefully. Our laTest CDCS Pdf file materials will ease your annoyance while preparing & reading, and then get better benefits and good opportunities.

New CDCS Exam Discount: https://www.2pass4sure.com/EPI-Data-Centre/CDCS-actual-exam-braindumps.html

What's more, part of that 2Pass4sure CDCS dumps now are free: https://drive.google.com/open?id=1mi-4oMkZD2poCw1Oyoe5vz17nw0OSPhY

Report this page